• Industrial Grade Dupont™ SFP-2880 Ultrafiltration Module – 77 m² For Water Purification
  • Industrial Grade Dupont™ SFP-2880 Ultrafiltration Module – 77 m² For Water Purification
  • Industrial Grade Dupont™ SFP-2880 Ultrafiltration Module – 77 m² For Water Purification
Industrial Grade Dupont™ SFP-2880 Ultrafiltration Module – 77 m² For Water Purification

Industrial Grade Dupont™ SFP-2880 Ultrafiltration Module – 77 m² For Water Purification

Detalhes do produto:

Lugar de origem: China
Marca: Dupont
Certificação: CE
Número do modelo: SFP-2880
Documento: UF-IntegraTec-P-Series-PVDF...en.pdf

Condições de Pagamento e Envio:

Quantidade de ordem mínima: 1 unidade
Preço: negociável
Detalhes da embalagem: Embalagem padrão de exportação
Tempo de entrega: 5-8 dias de trabalho
Termos de pagamento: ,T/T
Habilidade da fonte: 60000 unidades por mês
Melhor preço Contato

Informação detalhada

Faixa de fluxo deste componente: 40°90 LMH (24°53 gfd) a 25°C Taxa de fluxo deste componente: 2.0·6,9 m3/h (8,8·30,4 gpm)
Limites de temperatura deste componente: 1–40°C (34–104°F) TMP operacional máximo deste componente: 2,1 bar (30,5 psi)
Tolerância Química deste componente: Suporta até 2.000 mg/l naocl Design otimizado deste componente: 77m2
Ampla faixa de aplicação deste componente: Adequado para tratamento de água superficial, água do mar, Produção Municipal de Água Potável Tipo de membrana: Componentes de Membrana de Ultrafiltração de Grau Industrial

Descrição de produto

Industrial Grade Dupont™ SFP-2880 Ultrafiltration Module – 77 m²  For Water Purification
Product Overview

The Dupont™ SFP-2880 is an industrial ultrafiltration module featuring high-strength PVDF hollow fiber membranes with 77 m² of filtration area. Its 0.03 µm pore size effectively removes bacteria, viruses, and colloids, making it an ideal pretreatment for RO systems. Designed in an 8-inch diameter, outside-in configuration, it handles high-solid feed water with minimal pretreatment, ensures reliable performance, and reduces cleaning frequency. Suitable for surface water, seawater, and wastewater applications.

Key Features
  • Advanced Filtration Performance: Removes bacteria, viruses, and colloids with high efficiency; achieves filtrate turbidity below 0.1 NTU and SDI under 2.5; ideal protection for reverse osmosis systems
  • Engineered Durability: Chemical-resistant PVDF membrane withstands extreme pH conditions; U-PVC housing eliminates need for pressure vessels; operating temperature range supports global deployments
  • High-Efficiency Design: Industry-leading membrane area enables high flow rates; outside-in flow handles high solids loading; reduced backwash frequency lowers water consumption
  • Operational Reliability: Consistent performance in municipal and industrial settings; minimal maintenance requirements; compatible with automated control systems
Technical Specifications
Attribute Value
UF Module Flux Range 40–90 LMH (24–53 gfd) at 25°C
Flow Rate per Module 2.0–6.9 m³/hr (8.8–30.4 gpm)
UF Module Temperature Limits 1–40°C (34–104°F)
UF Module Max Operating TMP 2.1 bar (30.5 psi)
Chemical Tolerance Withstands up to 2,000 mg/L NaOCl
Membrane Area 77m²
Membrane Type Industrial Grade Ultrafiltration Membrane Components
Product Specifications
Model Type Part # Membrane Area (m²/ft²) Volume (Liters/Gallons) Weight (Kg/lbs)
SFP-2880 Pretreatment 280934 77 / 829 39 / 10.3 61 / 135 (empty), 100 / 220 (water filled)
SFD-2880 NSF/ANSI 61 Drinking water 324169 77 / 829 39 / 10.3 61 / 135 (empty), 100 / 220 (water filled)
Industrial Grade Dupont™ SFP-2880 Ultrafiltration Module – 77 m² For Water Purification 0
Operating Parameters
Parameter SI Units US Units
Filtrate Flux @ 25ºC 40-120 l/m²/hr 24-70 gfd
Flow range 3.1-9.3 m³/hr 13.6 - 40.9 gpm
Temperature 1-40ºC 34-104ºF
Max. inlet module pressure (@ 20ºC) 6.25 bar 93.75 psi
Max. operating TMP 2.1 bar 30 psi
Max operating air scour flow 12 nm³/hr 7.1 scfm
Max backwash pressure 2.5 bar 36 psi
Operating pH 2-11
Important: If operating limits and guidelines given in this bulletin are not strictly followed, the limited warranty will be null and void. To prevent biological growth during system shutdowns, it is recommended that preservative solution be injected into the membrane modules.
Module Installation
Industrial Grade Dupont™ SFP-2880 Ultrafiltration Module – 77 m² For Water Purification 1 Industrial Grade Dupont™ SFP-2880 Ultrafiltration Module – 77 m² For Water Purification 2